5.27 CONFIGURING SINGLE AND MULTIPLE ICS
The controller may be configured for a single output, 2-phase mode or a dual output voltage mode. In the
dual output mode the input voltages and the output voltages are independent of each other. In 2-phase
mode the input voltages and output voltages are tied together, respectively and certain other pins must be
configured. The two phases of a single controller are always 180° out-of-phase. The entry inTable 5-3 that
refer to "TO NETWORK" means the normal resistor-capacitor network used for control loop compensation.
The other entries refer to components that are typically connected to the device pin.
Table 5-2. Configuring Clock Mode
TIMING RESISTANCE VOLTAGE (V) CLOCK MODE
< 0.7 V (resistor to GND) Master (or single device)
> 1 V (tied to VREG or VDD) Slave
5.27.1 Single Device Operation
A single controller may be configured as a 2-phase or dual output. A summary of the modes and device
pin connections for a single controller is given in Table 5-3. The basic schematic of a single controller
operating in a 2-phase mode is shown in Figure 5-11 . The dual output schematic is shown in Figure 5-14.
Table 5-3. TPS40140 Single Device Mode Selection and Pin Configuration
DEVICE PIN FOR 2 PHASE MODE FOR DUAL OUTPUT MODE
COMP1 TO NETWORK TO NETWORK
COMP2 COMP1 TO NETWORK
TRK1 TO SS CAPACITOR TO SS CAPACITOR
TRK2 TO BP5 TO SS CAPACITOR
ILIM1 TO SET RESISTORS TO SET RESISTORS
ILIM2 GND TO SET RESISTORS
FB1 TO NETWORK TO NETWORK
FB2 GND TO NETWORK
PHSEL GND GND
PGOOD1 TO PULL-UP RESISTOR TO PULL-UP RESISTOR
PGOOD1 TO PULL-UP RESISTOR TO PULL-UP RESISTOR
CLKIO OPEN OPEN
28 APPLICATION INFORMATION Copyright © 2005–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: TPS40140