5.17 OVERTEMPERATURE
If the temperature of the controller die is detected to be above 155°C, the upper and lower MOSFETs are
turned off and the 5-V regulator, VREG, is turned off. When the die temperature decreases 30°C the
controller performs a normal start up.
5.18 FAULT MASKING OPERATION
If the TRKx pin voltage is externally limited below the 1.4-V threshold, the controller does not respond to
an Undervoltage fault and the PGOOD output remains low. Other fault modes remain operational. The
overcurrent protection continues to terminate PWM cycle every time the threshold is exceeded, but the
hiccup mode is not entered.
5.19 PROTECTION AND FAULT MODES
There are modes of normal operation during start up and shut down as well various fault modes that may
be detected. It is often necessary to know the state of the upper and lower MOSFETs in these modes.
Table xx shows a summary of these modes and the state of the MOSFETs. A description of each mode
follows the table.
Table 5-1. Fault Mode Summary
MODE UPPER MOSFET LOWER MOSFET
Programmable UVLO_CEx = LOW OFF OFF
Power-on reset: fixed UVLO, BP5 < 4.25 V OFF OFF
Overcurrent OFF, hiccup mode OFF, hiccup mode
Output undervoltage OFF, hiccup mode OFF, hiccup mode
Output overvoltage OFF ON
CLKFLT, missing CLKIO at slave OFF OFF
PHSEL voltage > 4 V, or open to ground OFF OFF
Overtemperature OFF OFF
5.20 SETTING THE SWITCHING FREQUENCY
The clock frequency is programmed by the value of the timing resistor connected from the RT pin to
ground. See Equation 6. This equation gives the frequency for an 8-phase system. For a 6-phase system
the frequency is 1 1/3 times higher.
; (6)
f
PH
is a single phase frequency, kHz. The R
t
resistor value is expressed in kΩ. See Figure 5-6.
Copyright © 2005–2013, Texas Instruments Incorporated APPLICATION INFORMATION 21
Submit Documentation Feedback