SETTING CONTROLLER CONFIGURATION
By default, the controller operates at four-phase configuration. The alternate number of active phases is
programmed by connecting unused PWM outputs to BP5. (See Figure 1) For example, for three-phase
operation, the unused fourth phase output, PWM4, should be connected to BP5. For two-phase operation, the
second, PWM2, and the fourth, PWM4, outputs should be connected to BP5.
POWER UP
Capacitors connected to the BP5 pin and the soft-start pin set the power-up time. When EN is high, the capacitor
connected to the BP5 pin gets charged by the internal LDO as shown in Figure 2.