4.3 Startup/Shutdown Procedure
4.4 Output Ripple Voltage Measurement Procedure
Test Setup
Figure 4. Control Loop Measurement Setup
1. Increase V
IN
(V1) from 0 V to 5 Vdc.
2. Vary LOAD1 from 0 A tp 10 Adc
3. Vary V
IN
from 4.5 Vdc to 5.5 Vdc
4. Short TP21 to TP19 to disable switching and 3-state output.
5. Decrease LOAD1 to 0 A.
6. Decrease V
IN
to 0 Vdc.
1. Increase VIN from 0 V to 5 Vdc.
2. Adjust LOAD1 to desired load between 0 Adc and 10 Adc.
3. Adjust V
IN
to desired load between 4.5 Vdc and 5.5 Vdc.
4. Connect oscilloscope probe to TP15 and TP16 as shown in Figure 3 .