Datasheet

Setup
www.ti.com
2 Setup
This section describes the jumpers and connectors on the EVM as well as how to properly connect, set
up, and use the TPS3808G01EVM.
2.1 Input / Output Connector Descriptions
J1: RST
This connector is the RST output. Connect this output to a multimeter, oscilloscope, or external circuit
to verify that RST goes low when MONITOR VOLTAGE goes below its threshold.
J2: MR
This connector is the manual reset input of the TPS3808G01. Pulling this pin low causes the device to
signal a reset. For convenience, pull this pin low by placing a short across the connector.
J3: MONITOR VOLTAGE
This connector is the voltage to be monitored. Connect J3 to a power supply or other voltage source.
RST should transition low when this voltage drops below its threshold.
J4: VDD
This connector is the power-supply connection for the TPS3808G01. It can be between 1.7 V and 6.5
V.
J5: GND
This connector is the return connection for the input power supply. It is electrically connected to J6.
J6: GND
This connector is the return connection for the power supply to be monitored. It is electrically
connected to J5.
JP2: RST Pull-Up
Connecting a short across JP2 connects a 10-kΩ pull-up resistor to the RST output.
JP3: Reset Timer
The setting of this jumper configures the reset delay of the device as described in Table 1.
Table 1. Reset Timer Settings
Setting Description
Open No connection to CT;
reset delay set to 20 ms
Short connected CT connected to a timer capacitor;
across pins 1 and 2 reset delay set to 125 ms
Short connected CT connected to a pull-up resistor;
across pins 2 and 3 reset delay set to 300 ms
JP5: Fixed Rail
Short this jumper for use of a fixed-voltage TPS3808Gxx device.
JP4: Adjustable Rail
Short this jumper for use of the adjustable-voltage TPS3808G01.
2
TPS3808G01EVM SBVU015April 2010
Copyright © 2010, Texas Instruments Incorporated