Datasheet

"#$%#&%'&(
"#$%#)'*&(
"#$%*+##&(
SGLS227C − DECEMBER 2003 − REVISED JUNE 2007
www.ti.com
5
ABSOLUTE MAXIMUM RATINGS
(1)
Over operating free-air temperature, unless otherwise noted.
Supply voltage, V
DD
(2)
+7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
All other pins
(2)
−0.3 V to +7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum low-output current, I
OL
+5 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum high-output current, I
OH
−5 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input clamp current, I
IK
(V
I
< 0 or V
I
> V
DD
) ±10 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
DD
) ±10 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation See Dissipation Rating Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
−55°C to +125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
,
(3)
−65°C to +150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(1)
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only,
and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is
not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2)
All voltage values are with respect to GND. For reliable operation the device should not be continuously operated at 7 V for more than
t = 1000 h.
(3)
Long-term high-temperature storage and/or extended use at maximum recommended operating conditions may result in a reduction of overall
device life. See www.ti.com/ep_quality for additional information on enhanced plastic packaging.
DISSIPATION RATING TABLE
PACKAGE
T
A
< +25°C
POWER RATING
DERATING FACTOR
ABOVE T
A
= +25°C
T
A
= +70°C
POWER RATING
T
A
= +85°C
POWER RATING
DCK 321 mW 2.6 mW/°C 206 mW 167 mW
RECOMMENDED OPERATING CONDITIONS
MIN MAX UNIT
Supply voltage, V
DD
1.3 6 V
Input voltage, V
I
0 V
DD
+ 0.3 V
Q suffix devices −40 +125
°C
A
M suffix devices −55 +125
°
C