Datasheet

GND
1.8 V to 18 V
OUTA
OUTB
INA+
INB-
VDD
Device
5 V
12 V
V
ITP
INA+
OUTA
V
ITP
INB-
OUTB
To a reset or enable
input of the system.
R
1
(2.61 M )W
GND
1.8 V to 18 V
OUTA
OUTB
R
2
(8.06 k )W
R
3
(40.2 k )W
V
MON
(26.4 V to 21.7 V)
INA+
INB-
VDD
Device
To a reset or enable input
of the system.
TPS3700
www.ti.com
SBVS187C FEBRUARY 2012REVISED MAY 2013
NOTE: The inputs can monitor a voltage higher than V
DD
(max) with the use of an external resistor divider network.
Figure 21. Monitoring a Voltage Other Than V
DD
NOTE: In this case, OUTA is driven low when an undervoltage condition is detected at the 5-V rail and OUTB is driven low when an
overvoltage condition is detected at the 12-V rail.
Figure 22. Monitoring Overvoltage for One Rail and Undervoltage for a Different Rail
Copyright © 2012–2013, Texas Instruments Incorporated Submit Documentation Feedback 13
Product Folder Links: TPS3700