Datasheet

   
    
SLVS336B − DECEMBER 2000 − REVISED JANUARY 2007
3
FUNCTION TABLES
V
DD
> V
SW
V
OUT
> V
IT
V
DD
> V
BAT
MSWITCH MR V
OUT
BATTON RESET CEOUT
0 0 0 0 0 V
BAT
1 0 DIS
0 0 0 0 1 V
BAT
1 0 DIS
0 0 0 1 0 V
BAT
1 0 DIS
0 0 0 1 1 V
BAT
1 0 DIS
0 0 1 0 0 V
DD
0 0 DIS
0 0 1 0 1 V
DD
0 0 DIS
0 0 1 1 0 V
BAT
1 0 DIS
0 0 1 1 1 V
BAT
1 0 DIS
0 1 0 0 0 V
BAT
1 0 DIS
0 1 0 0 1 V
BAT
1 1 EN
0 1 0 1 0 V
BAT
1 0 DIS
0 1 0 1 1 V
BAT
1 1 EN
0 1 1 0 0 V
DD
0 0 DIS
0 1 1 0 1 V
DD
0 1 EN
0 1 1 1 0 V
BAT
1 0 DIS
0 1 1 1 1 V
BAT
1 1 EN
1 1 0 0 0 V
DD
0 0 DIS
1 1 0 0 1 V
DD
0 1 EN
1 1 0 1 0 V
BAT
1 0 DIS
1 1 0 1 1 V
BAT
1 1 EN
1 1 1 0 0 V
DD
0 0 DIS
1 1 1 0 1 V
DD
0 1 EN
1 1 1 1 0 V
BAT
1 0 DIS
1 1 1 1 1 V
BAT
1 1 EN
V
BAT
> V
BOK
BATTOK
0 0
1 1
CONDITION: V
OUT
> V
DD(min)
CEIN
CEOUT
0 0
1 1
CONDITION: Enabled
PFI > V
PFI
PFO
0 0
1 1
CONDITION: V
OUT
> V
DD(min)
www.ti.com