Datasheet
TPS28225
TPS28226
www.ti.com
SLUS710C –MAY 2006–REVISED APRIL 2010
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)
(1) (2)
TPS28225/6 VALUE UNIT
Input supply voltage range, V
DD
(3)
–0.3 to 8.8
Boot voltage, V
BOOT
–0.3 to 33
DC –2 to 32 or V
BOOT
+ 0.3 – V
DD
whichever is less
Phase voltage, V
PHASE
Pulse < 400 ns, E = 20 mJ –7 to 33.1 or V
BOOT
+ 0.3 – V
DD
whichever is less
Input voltage range, V
PWM
, V
EN/PG
–0.3 to 13.2
V
PHASE
– 0.3 to V
BOOT
+ 0.3, (V
BOOT
– V
PHASE
< 8.8) V
Output voltage range, V
UGATE
Pulse < 100 ns, E = 2 mJ V
PHASE
– 2 to V
BOOT
+ 0.3, (V
BOOT
– V
PHASE
< 8.8)
–0.3 to V
DD
+ 0.3
Output voltage range, V
LGATE
Pulse < 100 ns, E = 2 mJ –2 to V
DD
+ 0.3
ESD rating, HBM 2 k
ESD rating, HBM ESD rating, CDM 500
Continuous total power dissipation See Dissipation Rating Table
Operating virtual junction temperature range, T
J
–40 to 150
Operating ambient temperature range, T
A
–40 to 125
°C
Storage temperature, T
stg
–65 to 150
Lead temperature (soldering, 10 sec.) 300
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating
conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) These devices are sensitive to electrostatic discharge; follow proper device handling procedures.
(3) All voltages are with respect to GND unless otherwise noted. Currents are positive into, negative out of the specified terminal. Consult
Packaging Section of the Data book for thermal limitations and considerations of packages.
DISSIPATION RATINGS
(1)
DERATING FACTOR T
A
< 25°C T
A
=70°C T
A
= 85°C
BOARD PACKAGE R
qJC
R
qJA
ABOVE T
A
= 25°C POWER RATING POWER RATING POWER RATING
High-K
(2)
D 39.4°C/W 100°C/W 10 mW/°C 1.25 W 0.8 W 0.65 W
High-K
(3)
DRB 1.4°C/W 48.5°C/W 20.6 mW/°C 2.58 W 1.65 W 1.34 W
(1) These thermal data are taken at standard JEDEC test conditions and are useful for the thermal performance comparison of different
packages. The cooling condition and thermal impedance R
qJA
of practical design is specific.
(2) The JEDEC test board JESD51-7, 3-inch x 3-inch, 4-layer with 1-oz internal power and ground planes and 2-oz top and bottom trace
layers.
(3) The JEDEC test board JESD51-5 with direct thermal pad attach, 3-inch x 3-inch, 4-layer with 1-oz internal power and ground planes and
2-oz top and bottom trace layers.
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
MIN TYP MAX UNIT
Input supply voltage (TPS28225) 4.5 7.2 8
V
DD
Input supply voltage (TPS28226) 6.8 7.2 8 V
V
IN
Power input voltage for the TPS28225 3 32 V
–VDD
T
J
Operating junction temperature range –40 125 °C
Copyright © 2006–2010, Texas Instruments Incorporated Submit Documentation Feedback 5