absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Supply voltage, V
CC
−0.3 V to 15 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Regulator input voltage range, REG_IN V
CC
−0.3 V to 42 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, 1IN, 2IN, 1IN1, 1IN2, 1IN2
, 2IN1, 2IN2, 2IN2 −0.3 V to V
CC
+0.5 V. . . . . . . . . . . . . . . . .
Output voltage range, 1OUT, 2OUT −0.5 < V < V
CC
+0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous regulator output current, REG_OUT 25 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, 1OUT, 2OUT ±100 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation See Dissipation Rating Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating ambient temperature range, T
A
−40°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltages are with respect to device GND pin.
recommended operating conditions
MIN MAX UNIT
Regulator input voltage range 8 40 V
Supply voltage, V
CC
4 14 V
Input voltage, 1IN1, 1IN2, 1IN2, 2IN1, 2IN2, 2IN2, 1IN, 2IN −0.3 V
CC
V
Continuous regulator output current, REG_OUT 0 20 mA
Ambient temperature operating range −40 125 °C
TPS28xx electrical characteristics over recommended operating ambient temperature range,
V
CC
= 10 V, REG_IN open for TPS2811/12/13, C
L
= 1 nF (unless otherwise noted)
inputs
PARAMETER TEST CONDITIONS MIN TYP
†
MAX UNIT
V
CC
= 5 V 3.3 4 V
Positive-going input threshold voltage
V
CC
= 10 V 5.8 9 V
Positive-going input threshold voltage
V
CC
= 14 V 8.3 13 V
V
CC
= 5 V 1 1.6 V
Negative-going input threshold voltage
V
CC
= 10 V 1 4.2 V
Negative-going input threshold voltage
V
CC
= 14 V 1 6.2 V
Input hysteresis V
CC
= 5 V 1.6 V
Input current Inputs = 0 V or V
CC
−1 0.2 1 µA
Input capacitance 5 10 pF
†
Typicals are for T
A
= 25°C unless otherwise noted.
outputs
PARAMETER TEST CONDITIONS MIN TYP
†
MAX UNIT
High-level output voltage
I
O
= −1 mA 9.75 9.9
V
High-level output voltage
I
O
= −100 mA 8 9.1
V
Low-level output voltage
I
O
= 1 mA 0.18 0.25
V
Low-level output voltage
I
O
= 100 mA 1 2
V
Peak output current V
CC
= 10 V 2 A
†