Datasheet

    
   
SLVS132F − NOVEMBER 1995 − REVISED OCTOBER 2004
20
www.ti.com
APPLICATION INFORMATION
t − Time
T
A
= 25°C
V
CC
= 14 V
V
I
= 48 V
V
DS
(20 V/div, 0.5 µs/div)
I
D
(0.5 A/div, 0.5 µs/div)
Figure 33. Drain-Source Voltage vs Drain
Current, TPS2811 Driving an IRFD014
(Hex-1 Size)
t − Time
T
A
= 25°C
V
CC
= 14 V
V
I
= 48 V
V
DS
(20 V/div, 50 ns/div)
V
GS
(5 V/div, 50 ns/div)
Figure 34. Drain-Source Voltage vs
Gate-Source Voltage, at Turn-on,
TPS2811 Driving an IRFD014 (Hex-1 Size)
t − Time
T
A
= 25°C
V
CC
= 14 V
V
I
= 48 V
V
DS
(20 V/div, 50 ns/div)
V
GS
(5 V/div, 50 ns/div)
Figure 35. Drain-Source Voltage vs
Gate-Source Voltage, at Turn-off,
TPS2811 Driving an IRFD014 (Hex-1 Size)
t − Time
T
A
= 25°C
V
CC
= 14 V
V
I
= 80 V
V
DS
(50 V/div, 0.2 µs/div)
V
GS
(0.5 A/div, 0.2 µs/div)
Figure 36. Drain-Source Voltage vs Drain
Current, TPS2811 Driving an IRFD120
(Hex-2 Size)