Datasheet

TPS2590
SLUS960F JULY 2009REVISED MAY 2013
www.ti.com
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
ORDERING INFORMATION
DEVICE JUNCTION PACKAGE ORDERING CODE MARKING
TEMPERATURE
TPS2590 -40°C to 125°C RSA (4-mm x 4-mm QFN) TPS2590RSA TPS2590
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)
(1) (2)
VALUES UNIT
Input voltage range IN, OUT –0.3 to 25
V
Voltage range FLT –0.3 to 20
Output sink current FLT 10 mA
Input voltage range, EN –0.3 to 6 V
Input current, RTRY ( RTRY internally clamped to 3 V) RTRY = 0 V 35 uA
Voltage range CT
(3)
, IFLT
(3)
,ILIM
(3)
, RTRY –0.3 to 3
ESD rating, HBM 2 .5 k V
ESD rating, CDM 400
Operating junction temperature range, T
J
Internally Limited
°C
Storage temperature range, T
stg
–65 to 150
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating
conditions” is not implied. Exposure to absolute–maximum–rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to GND.
(3) Do not apply voltage to pin.
DISSIPATION RATINGS
(1) (2) (3) (4)
PACKAGE θ
JA
LOW K, °C/W θ
JA
HIGH K, °C/W θ
JA
BEST 4, °C/W
RSA 211 55 50
(1) Tested per JEDEC JESD51, natural convection. The definitions of high-k and low-k are per JESD 51-7and JESD 51-3.
(2) Low-k (2 signal - no plane, 3 in. by 3 in. board, 0.062 in. thick, 1 oz. copper) test board with the pad soldered, and an additional 0.12
in.2 of top-side copper added to the pad.
(3) High-k is a (2 signal – 2 plane) test board with the pad soldered.
(4) The best case thermal resistance is obtained using the recommendations per SLMA002A (2 signal - 2 plane with the pad connected to
the plane).
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
MIN NOM MAX UNIT
Input voltage range IN, OUT 3 20
Voltage range EN 0 5 V
Voltage range FLT 0 20
Output sink current FLT 0 1 mA
Voltage range RTRY 0 3 V
CCT 0.1 nF
Output current, IOUT 0 5.5 A
R
RFLT
49.9 200 kΩ
R
RLIM
40.2 100 kΩ
Junction temperature -40 125 °C
2 Submit Documentation Feedback Copyright © 2009–2013, Texas Instruments Incorporated
Product Folder Links: TPS2590