Datasheet

TPS2560
TPS2561
SLVS930A DECEMBER 2009 REVISED FEBRUARY 2012
www.ti.com
ELECTRICAL CHARACTERISTICS (continued)
over recommended operating conditions, V
/ENx
= 0 V, or V
ENx
= V
IN
(unless otherwise noted)
PARAMETER TEST CONDITIONS
(1)
MIN TYP MAX UNIT
SUPPLY CURRENT
I
IN_off
Supply current, low-level output V
IN
= 6.5 V, No load on OUTx, V
ENx
= 6.5 V or V
ENx
= 0 V 0.1 2.0 μA
R
ILIM
= 20 k 100 125 μA
I
IN_on
Supply current, high-level output V
IN
= 6.5 V, No load on OUT
R
ILIM
= 100 k 85 110 μA
I
REV
Reverse leakage current V
OUTx
= 6.5 V, V
IN
= 0 V T
J
= 25°C 0.01 1.0 μA
UNDERVOLTAGE LOCKOUT
UVLO Low-level input voltage, IN V
IN
rising 2.35 2.45 V
Hysteresis, IN T
J
= 25°C 35 mV
FAULTx FLAG
V
OL
Output low voltage, FAULTx I
FAULTx
= 1 mA 180 mV
Off-state leakage V
FAULTx
= 6.5 V 1 μA
FAULTx deglitch FAULTx assertion or de-assertion due to overcurrent condition 6 9 13 ms
THERMAL SHUTDOWN
OTSD2 Thermal shutdown threshold 155 °C
Thermal shutdown threshold in
OTSD 135 °C
current-limit
Hysteresis 20
(3)
°C
(3) These parameters are provided for reference only, and do not constitute part of TI's published specifications for purposes of TI's product
warranty.
4 Submit Documentation Feedback Copyright © 20092012, Texas Instruments Incorporated
Product Folder Link(s): TPS2560 TPS2561