TWO-LEVEL CURRENT-LIMIT CIRCUIT
Some applications require different current-limit thresholds depending on external system conditions. Figure 21
shows an implementation for an externally controlled, two-level current-limit circuit. The current-limit threshold is
set by the total resistance from ILIM to GND (see previously discussed Programming the Current-Limit Threshold
section). A logic-level input enables/disables MOSFET Q1 and changes the current-limit threshold by modifying
the total resistance from ILIM to GND. Additional MOSFET/resistor combinations can be used in parallel to
Q1/R2 to increase the number of additional current-limit levels.
NOTE
ILIM should never be driven directly with an external signal.
Figure 21. Two-Level Current-Limit Circuit