SLVS736B – FEBRUARY 2008 – REVISED NOVEMBER 2008 ........................................................................................................................................
www.ti.com
Figure 24. Overcurrent Latch-Off Using a Quad-NAND Gate
Some applications require different current-limit thresholds depending on external system conditions. Figure 25
shows an implementation for an externally controlled, two-level current-limit circuit. The current-limit threshold is
set by the total resistance from ILIM to GND (see previously discussed "Programming the Current-Limit
Threshold" section). A logic-level input enables/disables MOSFET Q1 and changes the current-limit threshold by
modifying the total resistance from ILIM to GND. Additional MOSFETs/resistor combinations can be used in
parallel to Q1/R2 to increase the number of additional current-limit levels.
NOTE:
ILIM should never be driven directly with an external signal.
Figure 25. Two-Level Current-Limit Circuit
22 Submit Documentation Feedback Copyright © 2008, Texas Instruments Incorporated
Product Folder Link(s): TPS2550 TPS2551