Datasheet

4.3 Adjusting the Short-Circuit Output Current-Limit
www.ti.com
EVM Setup
Figure 3. TPS2500EVM Short-Circuit Output Figure 4. TPS2500EVM Short-Circuit Output
Current and Current and
FAULT Status With J3 Shorting Jumper FAULT Status With J3 Shorting Jumper
Present. Absent.
The EVM provides two current-limit settings. If a different setting is required, then populate header J3 with
a shorting jumper and modify resistor R3 using the current limit resistor calculator, TI Literature Number
SLVC163 .
See the TPS2500/1 data sheet for the worst-case current-limit variation.
SLUU363 June 2009 TPS2500/1, Power-Distribution Switch 5
With Low Voltage Input EVM
Submit Documentation Feedback