Datasheet

Test Points
www.ti.com
5 Test Points
Table 1. TPS249xEVM Test Points
TEST POINT NAME DESCRIPTION
TP1 VIN Input voltage power supply
TP2 GND Ground
TP3 EN-UV Enable signal, high true (and under-voltage detection)
TP4 None
TP5 PROG Program input
TP6 CT Fault timer capacitor
TP7 OV Over-voltage detection
TP8 IMON Output current monitor
TP9 GATE Gate output
TP10 PG Power good signal, low true
TP11 FLT Fault signal, low true
TP12 VOUT Output voltage
TP13 GND Scope ground test point
TP14 GND Scope ground test point
TP15 GND Scope ground test point
TP16 GND Scope ground test point
TP17 GND Scope ground test point
TP18 SENSE Low-side sense resistor
6 Connectors
Table 2. Connectors
CONNECTOR DESCRIPTION
J1 Main power input, VIN
J3 Main power ground, GND
J2 Load
J4 Load ground, GND
7 Jumpers
None.
8 Switches
8.1 Enable Switch, S1
The Enable slide switch turns on the hot plug controller to ramp the output voltage .When the switch is off,
the output is off.
9 Indicators
Green LED indicator for Power Good (PG)
Red LED indicator for FAULT (FLT)
6
Using the TPS2492/3 Hot Swap Controller SLUU425A May 2010 Revised March 2011
Submit Documentation Feedback
Copyright © 20102011, Texas Instruments Incorporated