TPS2480/1EVM GUI Setup
4 TPS2480/1EVM GUI Setup
4.1 TPS2480/1EVM GUI Installation
If not already performed on the PC/laptop to be used for test, open the TPS2480/1 GUI (SLUC167) file,
and extract it to a known folder.
4.2 TPS2480/1EVM GUI Operation
• Navigate to the TPS2480_1EVM.exe file, and double-click it. A GUI as shown in Figure 2 or Figure 4
appears. For a detailed example of the equations running behind the GUI, see the TPS2480/81 data
sheet (SLUS939).
• Click the Calibrate tab of the GUI. A GUI form as shown in Figure 3 or Figure 5 appears.
• Type the appropriate Rshunt value into the text box (0.001 for TPS2480EVM-002/TPS2481EVM-001 or
0.005 for the High Voltage Application). Press the Enter Shunt Resistance GUI button.
• Type a value of 60 into Max Expected Current ± text box. Press the Enter Max Expected Current GUI
button.
• Type a value of 0.002 into Enter LSB text box. Press the Enter Current LSB GUI button.
• At this time, the Read Initial Cal Current pushbutton activates (right side of Calibrate form under
Second Calibration). Press the Read Initial Cal Current GUI button.
• Type the appropriate Measured Shunt Current value into the text box. Press the Compute New Full
Scale and Read Post Second Cal Current GUI button.
• Press the Write all Edited and then the Read all Reg buttons in sequence.