4 TPS2480/1EVM GUI Setup
4.1 TPS2480/1EVM GUI Installation
If not already performed on the PC/laptop to be used for test, open the TPS2480/1 GUI (SLUC167) file,
and extract it to a known folder.
4.2 TPS2480/1EVM GUI Operation
Navigate to the TPS2480_1EVM.exe file, and double-click it. A GUI as shown in Figure 2 or Figure 4
appears. For a detailed example of the equations running behind the GUI, see the TPS2480/81 data
sheet (SLUS939).
Click the Calibrate tab of the GUI. A GUI form as shown in Figure 3 or Figure 5 appears.
Type the appropriate Rshunt value into the text box (0.001 for TPS2480EVM-002/TPS2481EVM-001 or
0.005 for the High Voltage Application). Press the Enter Shunt Resistance GUI button.
Type a value of 60 into Max Expected Current ± text box. Press the Enter Max Expected Current GUI
button.
Type a value of 0.002 into Enter LSB text box. Press the Enter Current LSB GUI button.
At this time, the Read Initial Cal Current pushbutton activates (right side of Calibrate form under
Second Calibration). Press the Read Initial Cal Current GUI button.
Type the appropriate Measured Shunt Current value into the text box. Press the Compute New Full
Scale and Read Post Second Cal Current GUI button.
Press the Write all Edited and then the Read all Reg buttons in sequence.
Figure 2. TPS2481EVM-001 and TPS2480EVM-002 GUI Overview Form
5
SLUU370AJanuary 2010Revised June 2010 TPS2480 and TPS2481 Evaluation Module