EVM Assembly Drawing and Layout Guidelines
www.ti.com
Figure 11. Bottom Side Placement/Routing
6.2 Layout Guidelines
The TPS2480/1 circuit layout must follow power and EMI/ESD best-practice guidelines. A basic set of
recommendations include:
• Arrange the high-power devices so that current flows in a sequential, linear fashion.
• Place a good ground plane under the power planes and TPS2480/1.
• The TPS2480/81 must be placed close to the sense resistor and MOSFET using a Kelvin type
connection to achieve accurate current sensing.
• A low-impedance GND connection is required because the TPS2480/81 can momentarily sink upwards
of 100 mA from the gate of the MOSFET. The GATE amplifier has high bandwidth while active, so
keep the GATE trace length short.
• Spacing consistent with safety standards like IEC60950 must be observed between the 48-V input
voltage rails and between the input and an isolated converter output.
• Large copper fills and traces must be used on SMT power-dissipating devices, and wide traces or
overlay copper fills must be used in the power path.
• The PROG, TIMER, and EN pins have high input impedances; therefore, their input lead length must
be minimized.
• Oversize power traces and power device connections assuring low voltage drop and good thermal
performance.