Datasheet

5 Test Set-Up
5.1 Equipment Requirement
TP4
TP5
TP6
TPS2459EVM-001
ATCA
TM
AdvancedMC
TM
ControllerwithI
2
C
12VIN
J1
GND
J3
3V3IN
J2
12-VPOWER
SUPPLY
+-
3.3-VPOWER
SUPPLY
+-
OSCILLOSCOPE
CH1
CH2
CH3
CH4
www.ti.com
Test Set-Up
The following test and interface equipment (not supplied) is required to verify EVM module operation, and
begin using the EVM.
Power supply, 3.3 VDC, 500 mA minimum
Power supply, 15 VDC, 10 A minimum
Digital multimeters
Oscilloscope, 4 channel, with current probe
Connect the TPS2458EVM and test equipment as shown in Figure 2 for functional check-out of the board
and a good starting point for user evaluation of device operation. Screen print labeling on the board
employs a naming convention in keeping with the nomenclature of the target ATCA™ and MicroTCA™
applications. Input 3.3-V supply is connected to the 3V3IN jack, and the 12-V supply is connected to the
12VIN jack. A cross-reference of power rail labeling to standards naming is shown in Table 3 .
Figure 2. Connection Diagram
Note: Run separate leads from the GND jacks back to a common return point made near the
power supply output terminals.
Table 3. TPS2458EVM Output Net and Jack Naming
REF DES CONNECTOR LABEL DESCRIPTION
J4 SLOT PWR AdvancedMC™ Slot Payload Power
J5 SLOT MP AdvancedMC™ Slot Management Power
J6 GND Common load return node
SLUU348A February 2009 Revised August 2009 TPS2458 ATCA™ AdvancedMC™ Controller 5
Submit Documentation Feedback