Datasheet

8 Getting Started (example)
8.1 Equipment Connections
Power
Supply
12V@10A
Scope
Current
Probe
220uF 15O
J1
J2
J4
J5
+
-
EN/ Vout
PG/
Note:
Connects to Scope
8.2 Operation
www.ti.com
Getting Started (example)
Reference Figure 5 for equipment connections.
Input power supply positive voltage to J1 and negative voltage to GND, J2. Connectors J1 and J2 can
accept #6 ring or spade lugs.
RC load at J4 and the load return at J5. The example here uses 220 µ F, 15 .
Scope to current probe to measure the load current.
Scope the V
OUT
- TP8, EN - TP3, PG - TP5.
Figure 5. Equipment Connections
Turn on the power supply.
Trigger the scope on EN low going edge.
Slide the EN to the EN position as screened on the circuit board.
SLUU343 January 2009 TPS2420 Hot Swap Controller System Test Board 9
Submit Documentation Feedback