Datasheet

TPS2421-1
TPS2421-2
www.ti.com
SLUS907G JANUARY 2009REVISED MAY 2013
ELECTRICAL CHARACTERISTICS
Unless otherwise noted: 3 V V
VIN
18 V, EN = 0 V, PG = FLT = open, R
OUT
= open, R
RSET
= 49.9 k, –40°C T
J
125°C,
No external capacitor connected to VOUT
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
VIN
UVLO VIN rising 2.6 2.85 2.9 V
Hysteresis 150 mV
Bias current EN = 2.4V 25 100 μA
EN = 0V 3.9 5 mA
VIN, VOUT
R
ON
R
VIN-VOUT
, I
VOUT
< I
LIM
, 1 A I
VOUT
4.5 A 33 50 m
Power limit TPS242x V
VIN
: 12 V, C
OUT
= 1000 μF EN: 3 V 0 V 3 5 7.5
V
Reverse diode
V
VOUT
> V
VIN
, EN = 5 V, I
VIN
= –1 A 0.77 1.0
voltage
ISET
I
VOUT
, I
CT
: sinking sourcing, pulsed test
R
RSET
= 200 k 0.80 1.2
0°C T
J
85°C R
RSET
= 100 k 1.80 2.2
Fault current
I
SET
R
RSET
= 49.9 k 3.60 4.40 A
threshold
R
RSET
= 200 k 0.75 1.25
-40°C T
J
125°C R
RSET
= 100 k 1.75 2.25
R
RSET
= 49.9 k 3.60 4.40
R
RSET
= 200 k 1.1 1.8 2.6
I
LIM
/
Ratio I
LIM
/ I
SET
R
RSET
= 100 k 1.1 1.5 2.1
I
SET
R
RSET
= 49.9 k 1.1 1.4 1.6
R
RSET
= 200 k 1.1 1.8 2.4
I
LIM
Current limit I
VOUT
rising, V
VIN-VOUT
= 0.3 V, pulsed test R
RSET
= 100 k 2.3 3.0 3.7
R
RSET
= 49.9 k 4.6 5.5 6.3
CT
I
CT
sourcing, V
CT
= 1 V, In current limit 29 35 41
Charge/discharge
μA
current
I
CT
sinking (-2), V
CT
= 1 V, drive CT to 1 V, measure current 1.0 1.4 1.8
V
CT
rising 1.3 1.4 1.5
Threshold voltage V
V
CT
falling, drive CT to 1 V, measure current 0.1 0.16 0.3
ON/OFF fault duty
V
VOUT
= 0 V 2.8% 3.7% 4.6%
cycle
Copyright © 2009–2013, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Links: TPS2421-1 TPS2421-2