Datasheet
www.ti.com
5.2 Power Supply Connection
5.3 Test Points
5.4 R
SET
500
0 003
SET
OFF
R
V .
æ ö
-
=
ç ÷
-
è ø
5.5 Test Methods
Procedure
Connect the power supplies and load to the TPS2410 test card as shown in Table 2 . Loading less than 30
A is safe for IRl3713S. The load can be a test load or the actual system load.
Table 2. Power Supply Connection
Connection Supply Terminal
+V PS1, J3
PS1
GND PS1GND, J27
+V PS2, J10
PS2
GND PS2GND, J11
5 V 5 V J15-2
5GND GND J15-1
Load + Load J5
Load - GND J7
Table 3 lists some common test points for observation. There are more test points shown on the
Schematic.
Table 3. Common Test Points
Function TP Channel 1 TP Channel 2
A TP3 TP11
C TP1 TP9
GATE TP6 TP14
R
SET
is used in TPS2411 to program the MOSFET turn-off point. The R
SET
calculation from the datasheet
is:
Calculate the R
SET
resistor and install. The component reference designators for both channels are
summarized in Table 4 .
Table 4. Table 5, R
SET
Resistor Setting
R
SET
CH1 CH2
Resistor R2 R4
The EVM has a few operating modes to view the system response. The user can make modifications to
the EVM to test in other ways.