Datasheet

LED Indicators
www.ti.com
3.6 Power Supply Connection
Connect the power supplies and load to the TPS2410 test card as shown in Table 3. Loading less than 30
A is safe for IRl3713S. The load can be a test load or the actual system load.
Table 3. Power Supply Connection
Connection Supply Terminal
PS1 +V PS1, J12
PS1 PS1, J312 IN1, J5
PS1 GND PS1GND, J10
PS2 +V PS2, J18
PS2 GND PS2GND, J19
5 V 5 V J20-2
5GND GND J20-1
Load + Load, +V J7
Load GND J11
3.7 OV and UV Setup
Set the OV and UV pots for each input voltage selected and re-adjust these pots when the input voltage
range is changed.
For this example, PS1 and PS2 are 12 V ±20 %. Set PS1 to the under-voltage set point, 9.6 V, and adjust
R13 until TP7 measures 0.6 V, reference Table 4. Set PS1 to the over-voltage set point, 14.4 V, and
adjust R12 until TP10 measures 0.6 V.
Complete this procedure for channel 2. Set the power supply voltages, PS1 and PS2, to the typical input,
12 V.
Table 4. UV and OV Setup
Supply Setting Potentiometer Test Point
PS1-UV R13 TP7
PS1-OV R12 TP10
PS2-UV R32 TP24
PS2-OV R31 TP26
3.8 Test Points
Table 5 lists some common test points for observation. There are more test points shown on the
schematic.
Table 5. Common Test Points
Function TP Channel 1 TP Channel 2
A TP2 TP18
C TP9
GATE TP11 TP22
OV INPUT TP10 TP26
UV INPUT TP7 TP24
FAULT TP8 TP25
PG TP4 TP20
6
TPS2410 EVM (HPA204) SLVU181A October 2006 Revised February 2012
Submit Documentation Feedback