Datasheet



SLUS471D − JUNE 2002 − REVISED JANUARY 2008
2
www.ti.com
ABSOLUTE MAXIMUM RATINGS (See Note 1)
TPS2390/1 UNIT
Input voltage range, all pins except RTN, EN, FAULT
(2)
−0.3 V to 15 V
Input voltage range, RTN
(2)
−0.3 V to 100 V
Input voltage range, EN
(2)(3)
−0.3 V to 100 V
Output voltage range, FAULT
(2)(4)
−0.3 V to 100 V
Continuous output current, FAULT 10 mA
Continuous total power dissipation see Dissipation Rating Table
Operating junction temperature range, T
J
−55_C to 125_C _C
Storage temperature range, T
stg
−65_C to 150_C _C
Lead temperature soldering 1,6 mm (1/16 inch) from case for 10 seconds 260_C _C
NOTES 1: Stresses beyond those listed under ”absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any other conditions beyond those indicated under ”recommended operating
conditions” is not implied. Exposure to absolute−maximum−rated conditions for extended periods may affect device reliability.
2: All voltages are with respect to −VIN (unless otherwise noted).
3: With 100-k minimum input series resistance, −0.3 V to 15 V with low impedance.
4: With 10-k minimum series resistance, −0.3 V to 80 V with low impedance.
ELECTROSTATIC DISCHARGE (ESD) PROTECTION
MIN UNIT
Human Body Model (HBM) 1.5 kV
Charged Device Model (CDM) 1.5 kV
RECOMMENDED OPERATING CONDITIONS†
MIN NOM MAX UNIT
Nominal input supply, −VIN to RTN −80 −36 V
Operating junction temperature range −40 85 _C
All voltages are with respect to −VIN (unless otherwise noted)
DISSIPATION RATING TABLE
PACKAGE T
A
< 25_C
POWER RATING
DERATING FACTOR
ABOVE T
A
= 25_C
T
A
= 85_C
POWER RATING
MSOP-8 420 mW 4.3 mW/_C 160 mW
AVAILABLE OPTIONS
OPERATING
FAULT
PACKAGED DEVICES
OPERATING
T
A
FAULT
OPERATION
PACKAGED DEVICES
MSOP (DGK)
−40_C to 85_C
Latch off TPS2390DGK
−40_C to 85_C
Periodically retry TPS2391DGK