Datasheet
www.ti.com
AUTO MODE FUNCTIONAL DESCRIPTION
Auto Mode
TPS23841
SLUS745A – NOVEMBER 2006 – REVISED MAY 2007
Auto mode (AM, MS = 0) operation is the basic approach for applying power to IEEE compliant PD’s. When AM
has been selected the TPS23841 automatically performs the following functions:
• Discovery of IEEE 802.3af compliant powered devices (PD's)
• Classification
• Power delivery
• Port over/under voltage detection, (if enabled, see Over/Under Voltage Fault section)
• Port over current detection (570 mA < I
PORT
< 665 mA
• Port maximum current limit (600 mA < I
PORT
< 700 mA)
• DC Disconnect (5 mA < I
PORT
< 10 mA)
• Thermal shutdown protection (TSD), (T
J
> 150 ° C)
• Internal oscillator watchdog
In AM the contents of all read registers are available via the I
2
C interface. In addition all control registers except
for the function bits can be written. This supports a semi-auto mode where the TPS23841 auto detects compliant
PD's while a host can access the A/D registers and class information and then implement power management
(including turning a port off, responding to faults, etc).
The write registers that are still active in AM are:
• All ports disable – Common Control register 0001b
• Over/Under Voltage Faults – Common Control register 0001b
• Software reset – Common Control register 0001b
• Disconnect disable – Port Control 1 register 0010b
• Discovery fault disable – Port Control 1 register 0010b
• Port enable – Port Control 2 register 0011b
For alternative B, semi-auto mode implementations which will manipulate the all ports disable or Port Enable
bits, please contact the factory for additional application information.
12