Datasheet
TPS2363
www.ti.com
SLUS680B –JANUARY 2006–REVISED JANUARY 2010
ABSOLUTE MAXIMUM RATINGS
Over operating free-air temperature range (unless otherwise noted)
(1)
PARAMETER VALUE UNIT
Supply 12 V, SH12A/B 0 to 15
Supply 3.3 V & SH33A/B, AUXINA/B 0 to 5
V
Logic input/output -0.5 to 5
VAUXA/B output voltage 0 to 5
VAUXA/B output current 1.4 A
FAULTA/B, PGOODA/B, INT sink current 10
mA
SDA sink current 10
Operating junction temperature -40 to 125
Storage temperature -65 to 150 °C
LEAD temperature soldering 260
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating
conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
ELECTROSTATIC DISCHARGE (ESD) PROTECTION
TEST METHOD MIN UNIT
HBM Human body model 2
kV
CDM Charged device model 1
DISSIPATION RATINGS
DERATING
T
A
≤ 25°C POWER
PACKAGE FACTOR ABOVE T
A
= 70°C POWER RATING T
A
= 85°C POWER RATING
RATING
T
A
= 25°C
PFB(48 TQFP) 1025.6 mW 10.256 mW/°C 564.1mW 410.3 mW
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
PARAMETER MIN NOM MAX UNIT
12 V input voltage range, SH12A/B 10.8 12 13.2
V
AUX and 3.3 V input voltage range, SH33A/B, AUXINA/B 3.0 3.3 3.6
VAUXA/B output current, PCI standard 375 mA
T
J
Operating junction temperature range -40 125
°C
T
A
Operating ambient temperature range -40 85
Copyright © 2006–2010, Texas Instruments Incorporated Submit Documentation Feedback 3