Datasheet

TPS2359
SLUS792H FEBRUARY 2008REVISED MAY 2013
www.ti.com
ORDERING INFORMATION
(1)
DEVICE TEMPERATURE PACKAGE
(2)
ORDERING INFORMATION
TPS2359 -40°C to 85°C QFN36 TPS2359RHH
(1) Add an R suffix to the device type for tape and reel.
(2) For the most current package and ordering information see the Package Option Addendum at the end of this document or see the TI
Web site at www.ti.com.
ABSOLUTE MAXIMUM RATINGS
(1)
over operating free-air temperature range (unless otherwise noted)
PARAMETER VALUE UNIT
PASSx, BLKx -0.3 to 30
IN12x; OUT12x; SENPx; SENMx; SETx; IRPT -0.3 to 17
IN3x; OUT3x; EN3x; VDDx; SUMx; SDA, SCL -0.3 to 5 V
AGND, GNDx -0.3 to 0.3
A0, A1, A2 0 to VINT
SUMx 5
VINT -1 to 1 mA
OUT3x Internally limited
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only. Functional operation of the device under any conditions beyond those indicated under recommended operating conditions is
neither implied nor guaranteed. Exposure to absolute maximum rated conditions for extended periods of time may affect device
reliability.
ELECTROSTATIC DISCHARGE (ESD) PROTECTION
TEST METHOD MIN UNITS
Human Body Model (HBM) 2
kV
Charged Device model (CDM) 0.5
DISSIPATION RATINGS
PACKAGE θJA - High-k (°C/W)
36 QFN 35
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
PARAMETER MIN TYP MAX UNIT
V
IN12x
Payload power input voltage 8.5 12 15
V
IN3x
Management power input voltage 3 3.3 4 V
V
VDD3x,3
Management power supply voltage 3 3.3 4
I
OUT3x
Management power output current 165 mA
I
SUMx
Summing pin current 100 1000
μA
PASSx pin board leakage current -1 1
VINT bypass capacitance 1 10 250 nF
T
J
Operating junction temperature range -40 125 °C
2 Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: TPS2359