Datasheet

TPS22980
SLVSB61C DECEMBER 2011REVISED SEPTEMBER 2013
www.ti.com
Figure 6. Allowable Voltage Transitions
Figure 7. Voltage Drop During Transitions from VHV
DIGITAL CONTROL SIGNALS
The voltage at OUT is controlled by two digital logic input signals, EN and HV_EN. HV_EN controls the state of
the VHV switch and EN controls the state of V3P3 switch. Table 1 lists the possible output states given the
conditions of the digital logic signals. State PD indicates a pulldown resistance of R
OUTDIS
to GND.
Table 1. Output State of OUT Given the States EN and
HV_EN
EN HV_EN OUT
0 0 PD
0 1 PD
1 0 V3P3
1 1 VHV
8 Submit Documentation Feedback Copyright © 2011–2013, Texas Instruments Incorporated
Product Folder Links :TPS22980