Datasheet
TPS22924C
www.ti.com
SLVSA52C –NOVEMBER 2009–REVISED JUNE 2013
ELECTRICAL CHARACTERISTICS
V
IN
= 0.75 V to 3.6 V (unless otherwise noted)
PARAMETER TEST CONDITIONS T
A
MIN TYP
(1)
MAX UNIT
V
IN
= 3.6 V 75 160
V
IN
= 2.5 V 42 70
V
IN
= 1.8 V 50 350
I
IN
Quiescent current I
OUT
= 0, V
IN
= V
ON
Full μA
V
IN
= 1.2 V 95 200
V
IN
= 1.0 V 65 110
V
IN
= 0.75 V 35 70
OFF-state supply
I
IN(LEAK)
V
ON
= GND, OUT = 0V Full 3.5 μA
current
25°C 18.3 19.7
V
IN
= 3.6 V
Full 26.0
25°C 18.5 19.5
V
IN
= 2.5 V
Full 25.8
25°C 19.6 21.8
V
IN
= 1.8 V
Full 27.4
r
ON
ON-state resistance I
OUT
= -200 mA mΩ
25°C 19.4 21.8
V
IN
= 1.2 V
Full 28.0
25°C 20.3 21.2
V
IN
= 1.0 V
Full 28.6
25°C 22.7 25.3
V
IN
= 0.75 V
Full 34.8
Output pulldown
r
PD
V
IN
= 3.3 V, V
ON
= 0, I
OUT
= 3 mA 25°C 1250 1500 Ω
resistance
(2)
ON-state input leakage
I
ON
V
ON
= 0.75 V to 3.6 V or GND Full 0.1 μA
current
(1) Typical values are at V
IN
= 3.3 V and T
A
= 25°C.
(2) See Output Pulldown in Application Information.
SWITCHING CHARACTERISTICS
V
IN
= 3.6 V, T
A
= 25°C (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
t
ON
Turn-ON time R
L
= 10 Ω, C
L
= 0.1 μF, V
IN
= 3.6 V 800 μs
t
OFF
Turn-OFF time R
L
= 10 Ω, C
L
= 0.1 μF, V
IN
= 3.6 V 3 μs
t
r
V
OUT
rise time R
L
= 10 Ω, C
L
= 0.1 μF, V
IN
= 3.6 V 800 μs
t
f
V
OUT
fall time R
L
= 10 Ω, C
L
= 0.1 μF, V
IN
= 3.6 V 2.5 μs
SWITCHING CHARACTERISTICS
V
IN
= 0.9 V, T
A
= 25°C (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
t
ON
Turn-ON time R
L
= 10 Ω, C
L
= 0.1 μF, V
IN
= 0.9 V 865 μs
t
OFF
Turn-OFF time R
L
= 10 Ω, C
L
= 0.1 μF, V
IN
= 0.9 V 20 μs
t
r
V
OUT
rise time R
L
= 10 Ω, C
L
= 0.1 μF, V
IN
= 0.9 V 500 μs
t
f
V
OUT
fall time R
L
= 10 Ω, C
L
= 0.1 μF, V
IN
= 0.9 V 5 μs
Copyright © 2009–2013, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: TPS22924C