Datasheet

80 m, single
TPS2041B-EP
SLVSAX8 SEPTEMBER 2011
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
ORDERING INFORMATION
(1)
NO. OF ORDERABLE TOP-SIDE
T
J
ENABLE PACKAGE
(2)
VID NUMBER
SWITCHES PART NUMBER MARKING
55°C to V62/11620-
Active low Single SOT-23 DBV TPS2041BMDBVTEP PXAM
125°C 01XE
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
web site at www.ti.com.
(2) Package drawings, thermal data, and symbolization are available at www.ti.com/packaging.
Figure 1. TPS2041B Switch at 500 mA
ABSOLUTE MAXIMUM RATINGS
(1)
over operating free-air temperature range unless otherwise noted
V
I(IN)
Input voltage range (IN)
(2)
0.3 V to 6 V
V
O(OUT)
Output voltage range (OUT)
(2)
0.3 V to 6 V
V
I(EN)
Input voltage range (EN) 0.3 V to 6 V
V
I(OC)
Voltage range (OC) 0.3 V to 6 V
I
O(OUT)
Continuous output current Internally limited
Continuous power dissipation at 125°C 182 mW
θ
JC
Thermal resistance, junction-to-case 55°C/W
T
J
Operating virtual-junction temperature range 55°C to 135°C
T
stg
Storage temperature range 65°C to 150°C
Lead temperature, soldering 1,6 mm (1/16 in) from case for 10 s 260°C
Human-Body Model (HBM) (H2) 2500 V
Electrostatic discharge (ESD) protection Machine Model (MM) (M0) 50 V
Charged-Device Model (CDM) (C5) 1500 V
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to GND.
RECOMMENDED OPERATING CONDITIONS
MIN MAX UNIT
V
I(IN)
Input voltage (IN) 2.7 5.5 V
V
I(EN)
Input voltage (EN) 0 5.5 V
I
O(OUT)
Continuous output current (OUT) 0 500 mA
T
J
Operating virtual-junction temperature 55 125 °C
2 Submit Documentation Feedback Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): TPS2041B-EP