Datasheet

www.ti.com
ELECTRICAL CHARACTERISTICS (Continued)
TPS2010A, TPS2011A
TPS2012A, TPS2013A
SLVS189C DECEMBER 1998 REVISED SEPTEMBER 2007
over recommended operating junction temperature range, V
I(IN)
= 5.5 V, I
O
= rated current, EN = 0 V (unless otherwise noted)
PARAMETER TEST CONDITIONS
(1)
MIN TYP MAX UNIT
SUPPLY CURRENT
T
J
= 25 ° C 0.3 1
Supply current, low-level output No Load on OUT EN = V
I(IN)
μ A
40 ° C T
J
125 ° C 10
T
J
= 25 ° C 58 75
Supply current, high-level output No Load on OUT EN = 0 V μ A
40 ° C T
J
125 ° C 75 100
Leakage current OUT connected to ground EN = V
I(IN)
40 ° C T
J
125 ° C 10 μ A
UNDERVOLTAGE LOCKOUT
Low-level input voltage 2 2.5 V
Hysteresis T
J
= 25 ° C 100 mV
(1) Pulse-testing techniques maintain junction temperature close to ambient temperature; thermal effects must be taken into account
separately.
6 Submit Documentation Feedback Copyright © 1998 2007, Texas Instruments Incorporated
Product Folder Link(s): TPS2010A, TPS2011A TPS2012A, TPS2013A