Datasheet

www.ti.com
ABSOLUTE MAXIMUM RATINGS
DISSIPATION RATINGS
RECOMMENDED OPERATING CONDITIONS
TPS2010A, TPS2011A
TPS2012A, TPS2013A
SLVS189C DECEMBER 1998 REVISED SEPTEMBER 2007
over operating free-air temperature range (unless otherwise noted)
(1)
VALUE UNIT
V
I(IN)
Input voltage range
(2)
0.3 to 6 V
V
O(OUT)
Output voltage range
(2)
0.3 to V
I(IN)
+ 0.3 V
V
I(EN)
Input voltage range 0.3 to 6 V
I
O(OUT)
Continuous output current Internally Limited
Continuous total power dissipation See Dissipation Rating Table
T
J
Operating virtual junction temperature range 40 to 125 ° C
T
stg
Storage temperature range 65 to 150 ° C
Lead temperature soldering 1,6 mm (1/16 inch) from case for 10 seconds 260 ° C
Human body model 2 kV
ESD Electrostatic discharge protection
Machine model 200 V
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to GND.
T
A
25 ° C DERATING FACTOR T
A
= 70 ° C T
A
= 85 ° C
PACKAGE
POWER RATING ABOVE T
A
= 25 ° C POWER RATING POWER RATING
D 725 mW 5.8 mW/ ° C 464 mW 377 mW
PWP 700 mW 5.6 mW/ ° C 448 mW 364 mW
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
I(IN)
2.7 5.5
Input voltage V
V
IH
0 5.5
TPS2010A 0 0.2
TPS2011A 0 0.6
I
O
Continuous output current A
TPS2012A 0 1
TPS2013A 0 1.5
T
J
Operating virtual junction temperature 40 125 ° C
4 Submit Documentation Feedback Copyright © 1998 2007, Texas Instruments Incorporated
Product Folder Link(s): TPS2010A, TPS2011A TPS2012A, TPS2013A