Datasheet

TPL8002-25
www.ti.com
SLIS133 NOVEMBER 2009
ABSOLUTE MAXIMUM RATINGS
(1) (2)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
DD
– V
EE
Power supply delta voltage
(3)
10 V
V
DD
Positive supply voltage range
(3)
–0.3 5 V
V
EE
Negative supply voltage range
(3)
0.3 –5 V
V
IN
Control input voltage range
(2) (3)
–0.3 V
DD
+ 0.3 V
V
I/O
Resistor I/O voltage range
(2) (3) (4)
V
EE
– 0.3 V
DD
+ 0.3 V
I
IK
Control input clamp current V
IN
< 0 and V
I/O
< 0 –18 mA
I
I/OK
I/O port clamp current V
IN
< 0 and V
I/O
< 0 –18 mA
T
stg
Storage temperature range –40 85 °C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to ground, unless otherwise specified.
(3) The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
(4) V
I
and V
O
are used to denote specific conditions for V
I/O
.
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
MIN TYP MAX UNIT
V
DD
– V
EE
Power supply delta voltage 8 V
V
DD
Positive supply voltage 2.5 3.6 4 V
V
EE
Negative supply voltage –2.5 –3.6 –4 V
V
IH
High-level control input voltage V
DD
× 0.65 V
V
IL
Low-level control input voltage V
DD
× 0.35 V
V
I
Control input voltage GND V
DD
V
V
I/O
Resistor inputs/outputs V
EE
V
DD
V
T
A
Operating free-air temperature –40 85 °C
Copyright © 2009, Texas Instruments Incorporated Submit Documentation Feedback 5