RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
DD,GND
2.7 5.5 V
V
H
, V
L
, V
W
Terminal Voltage Range 0 V
DD
V
V
DD
= 3.6 V to 5.5 V 2.4 5.5
V
IH
Voltage Input High (SCLK, DIN, CS) V
V
DD
= 2.7 V to 3.6 V 0.7 × V
DD
5.5
V
IL
Voltage Input Low (SCLK, DIN, CS) 0 0.8 V
I
W
Wiper Current ±2 mA
T
A
Ambient Temperature –40 85 °C
ABSOLUTE MAXIMUM RATINGS
(1)(2)(3)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
DD
to GND –0.3 7 V
Supply voltage range
All other pins
–0.3 V
DD
+ 0.3
to GND
I
L
Pulse Current ±20 mA
I
W
Continuous Current TPL0202-10 ±2 mA
I
H
θ
JA
RTE package 56.4
Package Thermal Impedance
(4)
°C/W
RUC package 216.7
T
stg
Storage temperature range –65 150 °C
(1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may
degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond
those specified is not implied.
(2) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum.
(3) All voltages are with respect to ground, unless otherwise specified.
(4) The package thermal impedance is calculated in accordance with JESD 51-7.
Copyright © 2010–2012, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Link(s): TPL0202