Datasheet

TPL0102
SLIS134B MARCH 2011 REVISED AUGUST 2011
www.ti.com
IVRB (Initial Value Register for Potentiometer B)
Register Address: 01H
Factory Programmed Value: 80H
Type: Non-volatile Write/Read
NAME SIZE (BITS) DESCRIPTION
IVRB 8 Non-volatile register to store wiper position for potentiometer B
WRB (Wiper Resistance Register for Potentiometer B)
Register Address: 01H
Reset Value: Same as IVRB
Type: Volatile Write/Read
NAME SIZE (BITS) DESCRIPTION
WRB 8 Volatile register to change wiper position for potentiometer B
ACR (Access Control Register)
Register Address: 00H
Reset Value: 40H
Type: Non-volatile Write/Read
NAME SIZE (BITS) DESCRIPTION
IVRA 8 Non-volatile register to store wiper position for potentiometer A
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
ACR 8
VOL SHDN WIP 0 0 0 0 0
Default Value 0 1 0 0 0 0 0 0
NAME SIZE (BITS) DESCRIPTION
0: Non-volatile registers (IVRA, IVRB) are accessible. Value written to IVRi register is
also written to the corresponding WRi.
VOL 1
1: Only Volatile Registers (WRi) are accessible.
0: Shut-down mode is enabled. Potentiometers are in shut-down mode.
(see Figure 2)
SHDN 1
1: Shut-down mode is disabled
0: Non-volatile write operation is not in progress
WIP (Read-only
1
1: Non-volatile write operation is in progress (it is not possible to write to the WRi or
bit)
ACR while WIP = 1)
10 Copyright © 2011, Texas Instruments Incorporated