Datasheet


    
SLIS095A − MARCH 2000 − REVISED MAY 2005
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
recommended operating conditions
MIN MAX UNIT
Logic supply voltage, V
CC
4.5 5.5 V
High-level input voltage, V
IH
0.85 V
CC
V
Low-level input voltage, V
IL
0.15 V
CC
V
Pulsed drain output current, T
C
= 25°C, V
CC
= 5 V (see Notes 3 and 5) 500 500 mA
Setup time, SER IN high before SRCK, t
su
(see Figure 2) 15 ns
Hold time, SER IN high after SRCK, t
h
(see Figure 2) 15 ns
Pulse duration, t
w
(see Figure 2) 40 ns
Operating case temperature, T
C
−40 125 °C
NOTES: 3. Pulse duration 100 µs and duty cycle 2%.
5. Technique should limit T
J
− T
C
to 10°C maximum.
electrical characteristics, V
CC
= 5 V, T
C
= 25°C (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
(BR)DSX
Drain-to-source breakdown voltage I
D
= 1 mA 50 V
V
SD
Source-to-drain diode forward
voltage
I
F
= 100 mA 0.85 1 V
V
OH
High-level output voltage,
I
OH
= −20 µA, V
CC
= 4.5 V 4.4 4.49
V
V
OH
High-level output voltage,
SER OUT
I
OH
= −4 mA, V
CC
= 4.5 V
4 4.2
V
V
OL
Low-level output voltage,
I
OL
= 20 µA, V
CC
= 4.5 V 0.005 0.1
V
V
OL
Low-level output voltage,
SER OUT
I
OL
= 4 mA, V
CC
= 4.5 V
0.3 0.5
V
I
IH
High-level input current V
CC
= 5.5 V, V
I
= V
CC
1 µA
I
IL
Low-level input current V
CC
= 5.5 V, V
I
= 0 −1 µA
I
CC
Logic supply current
All outputs off 20 100
A
I
CC
Logic supply current V
CC
= 5.5 V
All outputs on 150 300
µA
I
CC(FRQ)
Logic supply current at frequency
f
SRCK
= 5 MHz, C
L
= 30 pF,
All outputs off, See Figures 2 and 6
0.4 5 mA
I
N
Nominal current
V
DS(on)
= 0.5 V,
I
N
= I
D
,T
C
= 85°C
See Notes 5, 6, and 7 90 mA
I
DSX
Off-state drain current
V
DS
= 40 V, V
CC
= 5.5 V 0.1 5
A
I
DSX
Off-state drain current
V
DS
= 40 V, V
CC
= 5.5 V, T
C
= 125°C
0.15 8
µA
I
D
= 100 mA, V
CC
= 4.5 V 4.2 5.7
r
DS(on)
Static drain-source on-state
resistance
I
D
= 100 mA, T
C
= 125°C,
V
CC
= 4.5 V
See Notes 5 and 6
and Figures 7 and 8
6.8 9.5
resistance
I
D
= 350 mA, V
CC
= 4.5 V
and Figures 7 and 8
5.5 8
NOTES: 5. Technique should limit T
J
− T
C
to 10°C maximum.
6. These parameters are measured with voltage-sensing contacts separate from the current-carrying contacts.
7. Nominal current is defined for a consistent comparison between devices from different sources. It is the current that produces a
voltage drop of 0.5 V at T
C