Datasheet
SLIS095A − MARCH 2000 − REVISED MAY 2005
10
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
THERMAL INFORMATION
Figure 10
− Maximum Continuous Drain Current
MAXIMUM CONTINUOUS
DRAIN CURRENT OF EACH OUTPUT
vs
NUMBER OF OUTPUTS CONDUCTING
SIMULTANEOUSLY
N − Number of Outputs Conducting Simultaneously
of Each Output − A
D
I
0
123 4 5678
V
CC
= 5 V
T
C
= 25°C
T
C
= 125°C
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
T
C
= 100°C
Figure 11
− Maximum Peak Drain Current of Each Output − A
MAXIMUM PEAK DRAIN CURRENT
OF EACH OUTPUT
vs
NUMBER OF OUTPUTS CONDUCTING
SIMULTANEOUSLY
D
N − Number of Outputs Conducting Simultaneously
I
0.15
0.05
0.4
0
12 34 5
0.3
0.2
0.35
0.5
678
0.45
0.25
0.1
V
CC
= 5 V
T
C
= 25°C
d = t
w
/t
period
= 1 ms/t
period
d = 10%
d = 20%
d = 50%
d = 80%
Revision History
DATE REV PAGE SECTION DESCRIPTION
5/18/05 A 5 Figure 1 Changed SRCLR timing diagram
3/2000 * Original reversion
NOTE
: