switching characteristics, V
CC
= 5 V, T
C
= 25°C
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
t
PHL
Propagation delay time, high-to-low-level output from G 30 ns
t
PLH
Propagation delay time, low-to-high-level output from G
C
L
= 30 pF, I
D
= 350 mA,
125 ns
t
r
Rise time, drain output
C
L
= 30 pF, I
D
= 350 mA,
See Figures 1, 2, and 12
60 ns
t
f
Fall time, drain output
See Figures 1, 2, and 12
30 ns
t
a
Reverse-recovery-current rise time
I
F
= 350 mA, di/dt = 20 A/µs,
100 ns
t
rr
Reverse-recovery time
I
F
= 350 mA, di/dt = 20 A/µs,
See Notes 5 and 6 and Figure 5
300 ns
NOTES: 5. Technique should limit T
J
− T
C
to 10°C maximum.
6. These parameters are measured with voltage-sensing contacts separate from the current-carrying contacts.
thermal resistance
PARAMETER TEST CONDITIONS MIN MAX UNIT
R
JC
Thermal resistance, junction-to-case
DW
All eight outputs with equal power
10
°C/W
R
θJC
Thermal resistance, junction-to-case
NE
All eight outputs with equal power
10
°C/W
R
JA
Thermal resistance, junction-to-ambient
DW
All eight outputs with equal power
50
°C/W
R
θJA
Thermal resistance, junction-to-ambient
NE
All eight outputs with equal power
50
°C/W