Datasheet
SLIS010B − APRIL 1992 − REVISED MAY 2005
8
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
TYPICAL CHARACTERISTICS
Figure 9
STATIC DRAIN-SOURCE
ON-STATE RESISTANCE
vs
DRAIN CURRENT
I
D
− Drain Current − A
2
1.5
0.5
0
0.25 0.5 0.75 1
2.5
3.5
4
1.25 1.5
1
3
T
C
= 25°C
T
C
= 125°C
V
CC
= 5 V
See Note A
T
C
= − 40°C
Ω
DS(on)
− Static Drain-Source On-State Resistance −r
Figure 10
V
CC
− Logic Supply Voltage − V
0
0.5
1
1.5
2
2.5
3
34567
T
C
= 125°C
I
D
= 250 mA
See Note A
STATIC DRAIN-SOURCE
ON-STATE RESISTANCE
vs
LOGIC SUPPLY VOLTAGE
Ω
DS(on)
− Static Drain-Source On-State Resistance −r
T
C
= 25°C
T
C
= − 40°C
500
300
200
100
700
400
− 50 0 50 100 150
600
SWITCHING TIME
vs
FREE-AIR TEMPERATURE
t − Switching Time − ns
t
PHL
t
PLH
t
r
t
f
I
D
= 250 mA
See Note A
T
A
− Free-Air Temperature − °C
Figure 11
NOTE A: Technique should limit T
J
− T
C