TPIC6259
POWER LOGIC 8-BIT ADDRESSABLE LATCH
SLIS009A APRIL 1992 REVISED SEPTEMBER 1995
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443
HOUSTON, TEXAS 772511443
recommended operating conditions over recommended operating temperature range (unless
otherwise noted)
MIN MAX UNIT
Logic supply voltage, V
CC
4.5 5.5 V
High-level input voltage, V
IH
0.85 V
CC
V
Low-level input voltage, V
IL
0.15 V
CC
V
Pulsed drain output current, T
C
= 25°C, V
CC
= 5 V (see Notes 3 and 5) 1.8 1.5 A
Setup time, D high before G, t
su
(see Figure 2) 10 ns
Hold time, D high after G, t
h
(see Figure 2) 5 ns
Pulse duration, t
w
(see Figure 2) 15 ns
Operating case temperature, T
C
40 125 °C
electrical characteristics, V
CC
= 5 V, T
C
= 25°C (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
(BR)DSX
Drain-source breakdown voltage I
D
= 1 mA 45 V
V
SD
Source-drain diode forward voltage I
F
= 250 mA, See Note 3 0.85 1 V
I
IH
High-level input current V
CC
= 5.5 V, V
I
= V
CC
1 µA
I
IL
Low-level input current V
CC
= 5.5 V, V
I
= 0 1 µA
I
CC
Logic supply current I
O
= 0, All inputs low 15 100 µA
I
N
Nominal current
V
DS(on)
= 0.5 V, I
N
= I
D
, T
C
= 85°C,
See Notes 5, 6, and 7
250 mA
I
DSX
Off state drain current
V
DS
= 40 V 0.05 1
µA
I
DSX
Off
-
state
drain
current
V
DS
= 40 V, T
C
= 125°C 0.15 5
µ
A
I
D
= 250 mA, V
CC
= 4.5 V 1.3 2
r
DS(on)
Static drain-source on-state
resistance
I
D
= 250 mA, T
C
= 125°C,
V
CC
= 4.5 V
See Notes 5 and 6
and Figures 8 and 9
2 3.2
I
D
= 500 mA, V
CC
= 4.5 V 1.3 2
switching characteristics, V
CC
= 5 V, T
C
= 25°C
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
t
PLH
Propagation delay time, low-to-high-level output from D 625 ns
t
PHL
Propagation delay time, high-to-low-level output from D
C
L
= 30 pF, I
D
= 250 mA,
140 ns
t
r
Rise time, drain output
L
,
D
,
See Figures 1, 2, and 10
650 ns
t
f
Fall time, drain output 400 ns
t
a
Reverse-recovery-current rise time
I
F
= 250 mA, di/dt = 20 A/µs,
100
ns
t
rr
Reverse-recovery time
F
µ
See Notes 5 and 6 and Figure 3
300
ns
NOTES: 3. Pulse duration 100 µs, duty cycle 2%
5. Technique should limit T
J
T
C
to 10°C maximum.
6. These parameters are measured with voltage-sensing contacts separate from the current-carrying contacts.
7. Nominal current is defined for a consistent comparison between devices from different sources. It is the current that produces a
voltage drop of 0.5 V at T
C
= 85°C.
thermal resistance
PARAMETER TEST CONDITIONS MIN MAX UNIT
R
θJA
DW package
p
p
111
°C/W
R
θJA
-
-
N package
108
°C/W