Datasheet
SLIS056A − FEBRUARY 1995 − REVISED MARCH 1996
8
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
POST OFFICE BOX 1443
• HOUSTON, TEXAS 77251−1443
PRINCIPLES OF OPERATION
serial interface (continued)
Serial I/O Protocol (8-Bit Configuration)
Serial I/O Protocol (16-Bit Configuration)
Over
Temp
N/A 5 4 3 2 1 0
76543210
Unused
Global over-temperature flag
Output control data for Drain (0:5). Fault
data for Drain (0:5) is exclusive ORed and
transmitted in the respective bit locations.
Over
Temp
N/A 5 4 3 2 1 0
15 14 13 12 11 10
98
N/A 5 4 3 2 1 0
76543210
N/A
Output control data for Drain (0:5)
MSB LSB
MSB LSB
NOTE A: MSB is the first bit transferred.
Output control data for Drain (0:5). Fault
data for Drain (0:5) is exclusive ORed and
transmitted in the respective bit locations.
Unused
Global over-temperature flag
Figure 4. Serial Data Fault Protocol