www.ti.com
Absolute Maximum Ratings
(1)
Electrical Characteristics
ESD Protection
TPD3E001
LOW-CAPACITANCE 3-CHANNEL ± 15-kV ESD-PROTECTION ARRAY
FOR HIGH-SPEED DATA INTERFACES
SLLS683D JULY 2006 REVISED APRIL 2007
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
–0.3 7 V
V
I/O
–0.3 V
CC
+ 0.3 V
T
stg
Storage temperature range –65 150 ° C
T
J
Junction temperature 150 ° C
Infrared (15 s) 220
Bump temperature (soldering) ° C
Vapor phase (60 s) 215
Lead temperature (soldering, 10 s) 300 ° C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
V
CC
= 5 V ± 10%, T
A
= -40 ° c to 85 ° C (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
V
CC
Supply voltage 0.9 5.5 V
I
CC
Supply current 1 100 nA
V
F
Diode forward voltage I
F
= 10 mA 0.65 0.95 V
VBR Breakdown Voltage I
BR
= 10mA 11 V
Positive transients V
CC
+ 25
T
A
= 25 ° C, ± 15-kV HBM,
I
F
= 10 A
Negative transients –25
T
A
= 25 ° C, Positive transients V
CC
+ 60
± 8-kV Contact Discharge
V
C
Channel clamp voltage
(2)
V
Negative transients –60
(IEC 61000-4-2), I
F
= 24 A
T
A
= 25 ° C, Positive transients V
CC
+ 100
± 15-kV Air-Gap Discharge
Negative transients –100
(IEC 61000-4-2), I
F
= 45 A
I
i/o
Channel leakage current V
i/o
= GND or V
CC
± 1 nA
C
io
Channel input capacitance V
CC
= 5 V, bias of V
CC
/2 1.5 pF
(1) Typical values are at V
CC
= 5 V and T
A
= 25 ° C.
(2) Channel clamp voltage is not production tested.
PARAMETER TYP UNIT
HBM ± 15 kV
IEC 61000-4-2 Contact Discharge ± 8 kV
IEC 61000-4-2 Air-Gap Discharge ± 15 kV
3