Datasheet

TPD12S521
www.ti.com
SLVS639C OCTOBER 2007REVISED JANUARY 2013
ABSOLUTE MAXIMUM RATINGS
(1)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
5V_SUPPLY
Supply voltage 6 V
V
LV_SUPPLY
V
I/O
DC voltage at any channel input GND – 0.5 6 V
T
stg
Storage temperature range –65 150 °C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
MIN NOM MAX UNIT
Operating supply voltage 5V_SUPPLY 5 5.5 V
Bias supply voltage LV_SUPPLY 1 3.3 5.5 V
Operating temperature –40 85 °C
Copyright © 2007–2013, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: TPD12S521