Datasheet
EVM Configuration
www.ti.com
4 EVM Configuration
The TPD12S016 EVM has three separate sections,
the TOP, MIDDLE, and BOTTOM sections. Each
section includes a TPD12S016, input/output (IO) ports,
and jumper switches for enabling or disabling the
TPD12S016’s Level Shifter (LS), Hot Plug Detect and
5VOUT. VCC can be powered by either an HDMI input
or a 5V SUPPLY banana clip.
OUTPUT is side B; INPUT is side A. TOP, MIDDLE,
and BOTTOM sections are all supplied with power
using VBAT, VCCA, and GND.
1. The TOP section has Type-A HDMI male
connectors for IO.
2. The MIDDLE section has Type-C HDMI male
connectors for IO.
3. The BOTTOM section has a Type-A male
connector as input for the four differential pair
signals only. For probe testing of the high-speed
differential signals, test points are provided on the
board. Configurable output loads using R1-R8 &
C1-C4 are provided. This configuration provides a
means for developing eye diagrams under no load
or loaded conditions
Jumper Switch Configurations
LS (LS_OE) disabled enabled
CT_CP_HPD disabled enabled
5V
Using the +5Vout of TPD12S016 Bypass +5VOUT of TPD12S016
Selects source of output's +5
Power Signal (Pin 18)
2
TPD12S016 Evaluation Module SLLU154– September 2011
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated