Datasheet

TPD12S015
SLLSE19E DECEMBER 2009REVISED JUNE 2013
www.ti.com
Voltage Level Shifter: CEC Lines (x_A/x_B Ports)
T
A
= –40°C to 85°C unless otherwise specified
PARAMETER TEST CONDITIONS V
CCA
MIN TYP MAX UNIT
V
OHA
I
OH
= –10 μA, V
I
= V
IH
1.1 V to 3.6 V V
CCA
× 0.8 V
V
OLA
I
OL
= 10 µA, V
I
= V
IL
1.1 V to 3.6 V V
CCA
×
V
0.17
V
OHB
I
OH
= –10 μA, V
I
= V
IH
V
3P3
× 0.9 V
V
OLB
I
OL
= 3 mA, V
I
= V
IL
0.4 V
ΔV
T
CEC_A (V
T+
– V
T–
) 1.1 V to 3.6 V 40
mV
hysteresis
CEC_B (V
T+
– V
T–
) 1.1 V to 3.6 V 300
R
PU
(Internal pullup) CEC_A Internal pullup connected to 10
V
CCA
rail
kΩ
CEC_B Internal pullup connected to 26
internal 3.3 V rail
I
OFF
A port V
CCA
= 0 V, V
I
or V
O
= 0 to 3.6 V 0 V ±5
μA
B port 5VOUT = 0 V, V
I
or V
O
= 0 to 5.5 V 0 V to 3.6 V ±1.8
I
OZ
B port V
O
= V
CCO
or GND 1.1 V to 3.6 V ±5
μA
A port V
I
= V
CCI
or GND 1.1 V to 3.6 V ±5
Voltage Level Shifter: HPD Line (x_A/x_B Ports)
T
A
= –40°C to 85°C unless otherwise specified
PARAMETER TEST CONDITIONS V
CCA
MIN TYP MAX UNIT
V
OHA
I
OH
= –3 mA, V
I
= V
IH
1.1 V to 3.6 V V
CCA
× 0.7 V
V
OLA
I
OL
= 3 mA, V
I
= V
IL
1.1 V to 3.6 V V
CCA
V
×0.17
ΔV
T
HPD_B (V
T+
– V
T–
) 1.1 V to 3.6 V 700
mV
hysteresis
R
PD
(Internal pulldown) HPD_B, Internal pulldown connected 11
kΩ
to GND
I
OFF
A port V
O
= V
CCO
or GND 0 V ±5 μA
I
OZ
A port V
I
= V
CCI
or GND 3.6 V ±5 μA
LS_OE, CT_CP_HPD
T
A
= –40°C to 85°C unless otherwise specified
PARAMETER TEST CONDITIONS V
CCA
MIN TYP MAX UNIT
I
I
V
I
= V
CCA
or GND 1.1 V to 3.6 V ±12 μA
I/O Capacitance
T
A
= –40°C to 85°C unless otherwise specified
PARAMETER TEST CONDITIONS V
CCA
MIN TYP MAX UNIT
C
I
Control inputs V
I
= 1.89 V or GND 1.1 V to 3.6 V 7.1 8.5 pF
C
IO
A port V
O
= 1.89 V or GND 1.1 V to 3.6 V 8.3 9.5 pF
B port V
O
= 5.0 V or GND 1.1 V to 3.6 V 15 16.5 pF
8 Submit Documentation Feedback Copyright © 2009–2013, Texas Instruments Incorporated
Product Folder Links: TPD12S015