Datasheet

www.ti.com
10 500
0.001
10
0.01
0.1
1
THD+N − Total Harmonic Distortion + Noise − %
V
DD
= 3.3 V,
R
L
=16 Ω,
A
V
= −1 V/V,
C
B
= 1 µF
P
O
− Output Power − mW
1 kHz
20 kHz
100
20 Hz
20 20k100 1k 10k
0.001
10
0.01
0.1
1
THD+N − Total Harmonic Distortion + Noise − %
f − Frequency − Hz
V
DD
= 5 V,
P
O
= 100 mW,
C
B
= 1 µF,
R
L
= 16
A
V
= −10 V/V
A
V
= −1 V/V
A
V
= −5 V/V
10 500
0.001
10
0.01
0.1
1
THD+N − Total Harmonic Distortion + Noise − %
V
DD
= 5 V,
R
L
= 16 Ω,
A
V
= −1 V/V,
C
B
= 1 µF
P
O
− Output Power − mW
1 kHz
20 Hz
20 kHz
100
TPA6111A2
SLOS313B DECEMBER 2000 REVISED JUNE 2004
TOTAL HARMONIC DISTORTION + NOISE TOTAL HARMONIC DISTORTION + NOISE
vs vs
FREQUENCY OUTPUT POWER
Figure 11. Figure 12.
TOTAL HARMONIC DISTORTION + NOISE TOTAL HARMONIC DISTORTION + NOISE
vs vs
FREQUENCY OUTPUT POWER
Figure 13. Figure 14.