Datasheet
www.ti.com
20 20k100 1k 10k
0.001
10
0.01
0.05
0.1
1
THD+N − Total Harmonic Distortion + Noise − %
f − Frequency − Hz
V
DD
= 5 V,
P
O
= 60 mW,
C
B
= 1 µF,
R
L
= 32 Ω,
A
V
= −1 V/V
A
V
= −5 V/V
A
V
= −10 V/V
10 500
0.001
10
0.01
0.1
1
THD+N − Total Harmonic Distortion + Noise − %
V
DD
= 5 V,
R
L
= 32 Ω,
A
V
= −1 V/V,
C
B
= 1 µF
100
P
O
− Output Power − mW
1 kHz
20 Hz
20 kHz
20 20k100 1k 10k
0.001
10
0.01
0.1
1
THD+N − Total Harmonic Distortion + Noise − %
f − Frequency − Hz
V
DD
= 3.3 V,
P
O
= 100 mW,
C
B
= 1 µF,
R
L
= 10 kΩ,
A
V
= −1 V/V
A
V
= −10 V/V
A
V
= −1 V/V
A
V
= −5 V/V
20 20k100 1k 10k
0.001
10
0.01
0.1
1
THD+N − Total Harmonic Distortion + Noise − %
f − Frequency − Hz
V
DD
= 5 V,
P
O
= 100 mW,
C
B
= 1 µF,
R
L
= 10 kΩ
TPA6111A2
SLOS313B – DECEMBER 2000 – REVISED JUNE 2004
TOTAL HARMONIC DISTORTION + NOISE TOTAL HARMONIC DISTORTION + NOISE
vs vs
FREQUENCY OUTPUT POWER
Figure 3. Figure 4.
TOTAL HARMONIC DISTORTION + NOISE TOTAL HARMONIC DISTORTION + NOISE
vs vs
FREQUENCY FREQUENCY
Figure 5. Figure 6.
6