Datasheet
www.ti.com
TPA6011A4
SLOS392A – FEBRUARY 2002 – REVISED JULY 2004
Table 2. DC Volume Control (SE Mode, V
DD
= 5 V)
(1)
SE_VOLUME = VOLUME - SEDIFF or SEMAX
GAIN OF AMPLIFIER
(Typ)
FROM (V) TO (V)
0.00 0.26 -85
(2)
0.33 0.37 -46
0.44 0.48 -44
0.56 0.59 -42
0.67 0.70 -40
0.78 0.82 -38
0.89 0.93 -36
1.01 1.04 -34
1.12 1.16 -32
1.23 1.27 -30
1.35 1.38 -28
1.46 1.49 -26
1.57 1.60 -24
1.68 1.72 -22
1.79 1.83 -20
1.91 1.94 -18
2.02 2.06 -16
2.13 2.17 -14
2.25 2.28 -12
2.36 2.39 -10
2.47 2.50 -8
2.58 2.61 -6
(2)
2.70 2.73 -4
2.81 2.83 -2
2.92 2.95 0
(2)
3.04 3.06 2
3.15 3.17 4
3.26 3.29 6
(2)
3.38 3.40 8
3.49 3.51 10
3.60 3.63 12
3.71 5.00 14
(1) For other values of V
DD
, scale the voltage values in the table by a factor of V
DD
/5.
(2) Tested in production. Remaining gain steps are specified by design.
7