DEVICE CURRENT CONSUMPTION
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
32 52 72 92 112 132 152 172 192
fs-SamplingFrequency-kHz
I
-SupplyCurrent-mA
DD
V =3.6V
DD
V =3.3V
DD
V =3V
DD
BCLK=64fs
Data=24bit
SUPPLY CURRENT
vs
SAMPLINGFREQUENCY
TPA5050
SLOS492B MAY 2006 REVISED MAY 2007
The TPA5050 draws different amounts of supply current depending upon the conditions under which it is
operated. As V
DD
increases, so too does I
DD
. Likewise, as V
DD
decreases, I
DD
decreases. The same is true of
the sampling frequency, fs. An increase in fs causes an increase in I
DD
. Figure 11 illustrates the relationship
between operating condition and typical supply current.
Figure 11. Typical Supply Current